Attic Insulation Calculator

By , Editor Last reviewed

Pick your climate zone and tell us what's in the attic now. You get the R-value to add, from ENERGY STAR's recommendations, and how many bags of blown-in insulation or packages of batts that takes, read from your product's own label.

Your attic

Find yours on ENERGY STAR's map
sq ft
About the footprint of the top floor
Insulation there now
What you'll add
From the bag's chart, at the R-value you're adding
in
Same row of the chart
$

The default bag figures are Owens Corning AttiCat's chart for R-38. Other products and R-values differ: use your product's chart.

You need

R-49 to add

ENERGY STAR's figure for adding to 3–4 in of existing insulation in zone 5.

  • ENERGY STAR level for your zoneR-60
  • Blown-in insulation19 bags
  • Install at least13.5 in thick
  • Floors over unheated spaceR-30

On your bag's chart, use the row for at least R-49, and enter its bags per 1,000 sq ft and minimum thickness in the form.

Shopping list

  • 19 bags of blown-in insulation for R-49 over 1,000 sq ft, at least 13.5 in deep
  • Air sealing: caulk and canned foam for gaps around pipes, wires and the attic hatch
  • Attic rulers or depth markers, and a blowing machine (ask the store about rental)
  • Protective gear as the product label directs

Quick answer: in climate zone 5, ENERGY STAR recommends R-60 for an uninsulated attic, or adding R-49 if you already have 3–4 in. With Owens Corning AttiCat, its chart gives 19 bags per 1,000 sq ft for R-38; use your bag's chart for the R-value you need.

Recommended attic R-values by climate zone

ZoneUninsulated atticAdd to 3–4 in already thereFloor over unheated space
Zone 1R-30R-25R-13
Zone 2R-49R-38R-13
Zone 3R-49R-38R-19
Zone 4A or 4BR-60R-49R-19
Zone 4CR-60R-49R-30
Zone 5R-60R-49R-30
Zone 6R-60R-49R-30
Zone 7R-60R-49R-38
Zone 8R-60R-49R-38

Source: ENERGY STAR, based on the 2021 International Energy Conservation Code. Local code may require more for new work.

How the calculator works

R to add: ENERGY STAR level − R already there (or ENERGY STAR's own 3–4 in column)
Old insulation by depth: depth × 2.5 per inch (low end, so we don't overcount it)
Bags: area ÷ 1,000 × bags per 1,000 sq ft (from the label)
Batts: whole layers of your batt's R-value; packages = area × layers × (1 + extra%) ÷ coverage

We read coverage from the product label instead of a formula, because loose fill's coverage depends on the product and how it's blown. The label's chart is what the manufacturer stands behind.

R-value per inch, by material

MaterialR per inchNotes
Fiberglass batt or board2.5–4Not an air barrier; vapor control depends on the facing.
Mineral wool rigid board3–4PNNL lists the rigid board; batts weren’t in the table.
Expanded polystyrene (EPS) board3.8–4.4Typically a Class III vapor retarder.
Extruded polystyrene (XPS) board5Typically a Class II vapor retarder.
Polyisocyanurate (polyiso) board6–6.5PNNL: about 6; DOE’s guide: 6.5 for 1 in. Can lose some R-value as it ages, mostly in the first two years (DOE).
Closed-cell spray foam6–6.5PNNL: about 6 (high-density); DOE’s guide: 6.5 for 1 in.
Open-cell spray foam3.6DOE’s guide lists R-12.6 for 3.5 in (about 3.6 per inch). DOE says not to use it below ground level.

Sources: PNNL's Building America Solution Center and DOE's Guide to Home Insulation. DOE's live Energy Saver insulation pages returned “not found” when we checked on Oct 30, 2026, so we also cite an archived copy.

Example: blown-in depth by R-value

Owens Corning's AttiCat chart gives these minimum thicknesses. Settling, it says, “is negligible, with no impact on R-value.”

R-valueMinimum thickness
R-3010.75 in
R-3813.5 in
R-4917 in
R-6020.5 in

Do these first

Doing it yourself or hiring? Run the numbers with the DIY vs hire a pro calculator, and put the work in your project plan. Terms like R-value and vapor retarder are in the glossary.

Common questions

How much insulation do I need in my attic?

It depends on your climate zone. ENERGY STAR, using the 2021 International Energy Conservation Code, recommends R-30 for an uninsulated attic in zone 1, R-49 in zones 2 and 3, and R-60 in zones 4 to 8. If you already have 3–4 in, it recommends adding R-25 (zone 1), R-38 (zones 2–3) or R-49 (zones 4–8).

How many bags of blown-in insulation do I need?

Read it off the bag. Every loose-fill product has a coverage chart listing bags per 1,000 sq ft for each R-value. For example, Owens Corning's AttiCat chart gives 19 bags per 1,000 sq ft for R-38, so a 1,000 sq ft attic takes 19 bags. Enter your product's figure and your attic area above.

How deep should blown-in insulation be?

At least the minimum thickness on the bag chart for your R-value. For AttiCat, that is 10.75 in for R-30, 13.5 in for R-38, 17 in for R-49 and 20.5 in for R-60. Other products differ, so use your own bag’s chart.

Should I air seal before adding insulation?

Yes. ENERGY STAR estimates homeowners save an average of 15% on heating and cooling costs (11% of total energy costs) by air sealing and adding insulation. It also notes that, combined with attic insulation, air sealing can help reduce ice dams.

What is my climate zone?

The US is divided into zones 1 (hottest) to 8 (coldest) by county. ENERGY STAR’s insulation page has the map; your local building department can also tell you.

Sources

Formulas and figures last checked against these sources on. Spotted an error? Tell us and we'll fix it.

Plan the rest of the project

More calculators